By Editor , 27 October 2026
TDengine Guide: Historian Data Needs Context Before AI Training

Global – October 27, 2026 -- A historian export of tags and timestamps is rarely a training-ready dataset for Industrial AI, according to TDengine guidance that tells engineers to establish what each measurement means, when it happened, which asset produced it and whether it is reliable before data reaches an external model-training workflow.

By Editor , 27 October 2026
Knowledge Graphs give Industrial AI traceable plant context

Global – October 27, 2026 -- An Industrial Knowledge Graph links assets, measurements, events, documents and procedures as connected entities. This gives Industrial AI more relevant context than raw document search, according to a TDengine explainer for OT architects.

By Editor , 27 October 2026
Industrial AI Data Platforms Should Be Judged by One Decision

Global – October 27, 2026 -- Plants selecting an industrial data platform for AI should start with a single operational decision, such as whether a reliability engineer must review a compressed-air pressure drop within an hour, rather than with a list of AI features. That decision defines the required sources, history, context, access controls and response time.

By Editor , 27 October 2026
OPC UA Connection Test Proves Only Part of Historian Data Path

Global – October 27, 2026 -- A successful OPC UA connection check shows only that a client can reach the endpoint. It does not prove the intended nodes are readable, monitored, mapped or written to the historian, according to a five-step troubleshooting workflow for industrial data pipelines.

The method starts with one known, changing point, traced from the OPC UA server to one expected historian table. Large tag lists hide the first failure.

By Editor , 27 October 2026
TDengine Maps Three OPC UA Collection Modes to Historian Needs

Global – October 27, 2026 -- Industrial historians should default to data-change subscriptions for continuously monitored OPC UA process variables and reserve polling for explicitly periodic records, according to collection guidance tied to TDengine TSDB-Enterprise.

By Editor , 27 October 2026
OPC UA Historians Should Store Source Time and Receipt Time

Global – October 27, 2026 -- Choosing the wrong OPC UA timestamp can reorder events, hide network delay or place valid data outside the historian query window, so most process analysis should use a trustworthy SourceTimestamp as event time and keep collector receipt time as a separate field.

By Editor , 27 October 2026
Reconnected OPC UA Links Can Still Leave Historian Data Gaps

Global – October 27, 2026 -- A restored OPC UA connection does not guarantee that the historian holds every value generated during an outage, because the three links in the data path (source, collector and historian) each lose data in different ways. Buffering at one layer cannot repair a loss that occurred earlier in the chain.

By Editor , 27 October 2026
OPC UA vs MQTT: Match the Protocol to the Plant Data Role

Global – October 27, 2026 -- Industrial data architects should choose OPC UA when a collector must discover and read a structured source, and MQTT when producers publish through a broker to one or more consumers, according to a TDengine technical comparison. The guide adds that the two names do not describe equivalent layers, so the rule is only a starting point.

By Editor , 27 October 2026
OPC UA Historians Need Alarm Records, Not Just Tag History

Global – October 27, 2026 -- A pump pressure trend shows when a value left its normal range but cannot show which alarm changed state, what severity the server reported, or when an operator acknowledged it. Those answers sit in separate OPC UA records, and historian designs must decide which questions each record has to answer.